  circuit diagram l n l n e e r c x c y c y c x features north american and metric fuse holders available fuse holder and double pole power on/off switch provided in a convenient/compact package suitable for products that must conform to fcc and ftz requirements meets over voltage category ii of iec 664 and complies with iec 950 metal case provides effective emi shielding easy access fuse drawer with space for spare fuse flange-mounted or snap-in styles available for quick mounting operating temperature: -25 c to +85 c (including temperature rise, see graph on page 47) switched and fused filtered power entry modules for general purpose applications switched and fused filtered power entry modules 46 spectrum control inc. 8031 avonia rd. fairview, pa 16415 phone: 814-474-2207 fax: 814-474-2208 web site: www.spectrumcontrol.com spectrum control gmbh hansastrasse 6 91126 schwabach, germany phone: (49)-9122-795-0 fax: (49)-9122-795-58 tested and found to be iaw vde 0565 part 3. applications computers and peripheral equipment electronic equipment digital equipment measuring and testing instruments telecommunications equipment note: test voltage 1500vac one minute, line to ground insulation resistance: 300 m ? min. at 500vdc b(s) = bolt-in terminals or (snap-in terminals) voltage drop: 1v max. at rated current weight: 130g inlet: compatible with iec-320 * substitute bsf or ssf for xxx bsf - bolt-in switched and fused ssf - snap-in switched and fused specifications model* rated voltage rated leakage current capacitance inductance temperature (@ 50/60hz) current (max.) c y c x1 c x2 (l 1 ) rise (max.) 64-xxx-020-3-12 64-xxx-020-3-04 64-xxx-020-3-14 64-xxx-020-3-06 64-xxx-020-5-12 64-xxx-020-5-04 64-xxx-020-5-14 64-xxx-020-5-06 64-xxx-040-3-12 64-xxx-040-3-04 64-xxx-040-3-14 64-xxx-040-3-06 64-xxx-040-5-12 64-xxx-040-5-04 64-xxx-040-5-14 64-xxx-040-5-06 64-xxx-060-3-12 64-xxx-060-3-04 64-xxx-060-3-14 64-xxx-060-3-06 64-xxx-060-5-12 64-xxx-060-5-04 64-xxx-060-5-14 64-xxx-060-5-06 65-xxx-020-3-12 65-xxx-020-3-04 65-xxx-020-3-14 65-xxx-020-3-06 65-xxx-020-5-12 65-xxx-020-5-04 65-xxx-020-5-14 65-xxx-020-5-06 65-xxx-040-3-12 65-xxx-040-3-04 65-xxx-040-3-14 65-xxx-040-3-06 65-xxx-040-5-12 65-xxx-040-5-04 65-xxx-040-5-14 65-xxx-040-5-06 65-xxx-060-3-12 65-xxx-060-3-04 65-xxx-060-3-14 65-xxx-060-3-06 65-xxx-060-5-12 65-xxx-060-5-04 65-xxx-060-5-14 65-xxx-060-5-06 250vac 250vac 250vac 125vac 125vac 125vac 2a 45 c 10.5mh 10.5mh 4.2mh 4.2mh 1.6mh 1.6mh 45 c 45 c 45 c 45 c 45 c 0.35ma 2200pf 3300pf 0.22uf 0.47uf 0.22uf 0.47uf 0.22uf 0.47uf 0.22uf 0.47uf 0.22uf 0.47uf 0.22uf 0.47uf 0.22uf 0.47uf 0.22uf 0.47uf 0.22uf 0.47uf 0.22uf 0.47uf 0.22uf 0.47uf 0.22uf 0.47uf 2200pf 3300pf 2200pf 3300pf 2200pf 3300pf 2200pf 2200pf 0.50ma 0.35ma 0.50ma 0.35ma 0.50ma 0.35ma 0.50ma 0.35ma 0.50ma 0.35ma 0.50ma 4a 6a none 0.22uf none 0.47uf none 0.22uf none 0.47uf none 0.22uf none 0.47uf none 0.22uf none 0.47uf none 0.22uf none 0.47uf none 0.22uf none 0.47uf none 0.22uf none 0.47uf none 0.22uf none 0.47uf none 0.22uf none 0.47uf none 0.22uf none 0.47uf none 0.22uf none 0.47uf none 0.22uf none 0.47uf 2a 4a 6a 64-65-bsf/64-65-ssf series
50 ? level meter 50 ? 1 3 24 filter oscillator 50 ? common mode 50 ? level meter 50 ? 1 3 24 filter oscillator 50 ? 50 ? normal mode .248 (6.3) 2.556 (65) 2.348 (59.7) 1.313 (33.4) 1.101 (28) fast-on tab #250 2.273 (57.8) 1.133 (28.8) 2.340 (59.5) panel cutout dimension mount from back side 1.514 (38.8) a r .079 (2.0) thickness of panel a .031 (0.8t) 2.430 (61.8 0.1) .039 (1.0t) 2.446 ( 62.2 0.1) .047 (1.2t) 2.462 (62.6 0.1) .059 (1.5t) 2.470 (62.8 0.1) .071 (1.8t) 2.473 (62.9 0.1) .079 (2.0t) 2.477 (63.0 0.1) * general tolerance .039 (1.0) * metal case 1.16 (29.5 ) +0.5 -0 +.02 -0 t= .031 (0.8) dimensions in inches (mm) 0.35 ma leakage versions insertion loss (db) 80 frequency (mhz) 70 60 50 40 30 20 10 0 0.1 0.2 0.5 12 5 10 20 50 2 amp 4 amp 6 amp 90 0.50 ma leakage versions insertion loss (db) 80 frequency (mhz) 70 60 50 40 30 20 10 0 0.1 0.2 0.5 12 5 10 20 50 2 amp 4 amp 6 amp 90 64/65-b(s)sf-*-*-02(04,06) insertion loss (db) 80 frequency (mhz) 70 60 50 40 30 20 0 0.1 0.2 0.5 12 5 10 20 50 6 amp 90 100 4 amp 2 amp 64/65-b(s)sf-*-*-11(12,14) insertion loss (db) 80 frequency (mhz) 70 60 50 40 30 20 0 0.1 0.2 0.5 12 5 10 20 50 6 amp 90 100 4 amp 2 amp .248 (6.3) 2.556 (65) 2.348 (59.7) .142 (3.6) 1.947 (49.5) 1.573 (40 0.2) 1.101 (28) fast-on tab #250 2.273 (57.8) 1.133 (28.8) 2.340 (59.5) 1.573 ( 40. 0.2) 2.399 (61) panel cutout dimension mount from back side r .059 (1.5) 2 - .142 (3.6) hole 1.526 (38.8) 1.16 (29.5 ) 0.5 0 .334 0 t= .031 (0.8) switched and fused filtered power entry modules for general purpose applications 64/65-ssf series dimensions 64/65-bsf series temperature characteristics switched and fused filtered power entry modules 47 spectrum control inc. 8031 avonia rd. fairview, pa 16415 phone: 814-474-2207 fax: 814-474-2208 web site: www.spectrumcontrol.com spectrum control gmbh hansastrasse 6 91126 schwabach, germany phone: (49)-9122-795-0 fax: (49)-9122-795-58 120 100 80 60 40 20 0 20 30 40 50 60 70 80 90 ambient temperature ( c) current (%) temperature characteristics
l n l n e e c y1 c y2 line load r c x1 l 1 c x2 note: c y1 and c y2 capacitors omitted on 66/67 b(s)f-xxx-1-x filters circuit diagram weight: 130g inlet: compatible with iec-320 b(s) = bolt-in terminals or (snap-in terminals) * substitute bsf or ssf for xxx bsf - bolt-in switched and fused ssf - snap-in switched and fused features metric and north american fuse holders available fuse holder and a double pole power on/off switch provides a convenient/compact package suitable for products that must conform to fcc and ftz requirements meets over voltage category ii of iec 664 and complies with iec 950 provides susceptibility protection without the leakage current associated with line-to-ground capacitors designed to meet requirements for non-patient and patient care equipment metal case provides effective emi shielding easy access fuse drawer - space for spare fuse flange-mounted or snap-in styles available for quick mounting operating temperature: -25 c to +85 c (including temperature rise, see graph on page 49) applications medical equipment industrial equipment telecommunications equipment measuring and testing instruments digital equipment (including switching power supplies) general purpose filter for susceptibility or high frequency clean up applications switched and fused filtered power entry modules for medical or general purpose applications 48 spectrum control inc. 8031 avonia rd. fairview, pa 16415 phone: 814-474-2207 fax: 814-474-2208 web site: www.spectrumcontrol.com spectrum control gmbh hansastrasse 6 91126 schwabach, germany phone: (49)-9122-795-0 fax: (49)-9122-795-58 10.5mh 4.2mh 1.6mh 2a 4a 6a 125 vac 40 c 45 c 67-xxx-020-0-12 67-xxx-020-0-04 67-xxx-020-0-14 67-xxx-020-0-06 67-xxx-020-1-12 67-xxx-020-1-04 67-xxx-020-1-14 67-xxx-020-1-06 67-xxx-020-4-12 67-xxx-020-4-04 67-xxx-020-4-14 67-xxx-020-4-06 67-xxx-040-0-12 67-xxx-040-0-04 67-xxx-040-0-14 67-xxx-040-0-06 67-xxx-040-1-12 67-xxx-040-1-04 67-xxx-040-1-14 67-xxx-040-1-06 67-xxx-040-4-12 67-xxx-040-4-04 67-xxx-040-4-14 67-xxx-040-4-06 67-xxx-060-0-12 67-xxx-060-0-04 67-xxx-060-0-14 67-xxx-060-0-06 67-xxx-060-1-12 67-xxx-060-1-04 67-xxx-060-1-14 67-xxx-060-1-06 67-xxx-060-4-12 67-xxx-060-4-04 67-xxx-060-4-14 67-xxx-060-4-06 none 0.22uf none 0.22uf none 0.22uf none 0.22uf none 0.22uf none 0.22uf none 0.22uf none 0.22uf none 0.22uf none 0.22uf none 0.22uf none 0.22uf none 0.22uf none 0.22uf none 0.22uf none 0.22uf none 0.22uf none 0.22uf note: test voltage: 1500vac one minute, line to ground insulation resistance: 300 m ? min. at 500vdc voltage drop: 1v max. at rated current rated rated leakage temp. model* voltage current current capacitance induct. rise 50/60hz (max.) c y c x1 c x2 (l 1 ) (max.) 0.22uf 0.47uf 0.22uf 0.47uf 0.22uf 0.47uf 0.22uf 0.47uf 0.22uf 0.47uf 0.22uf 0.47uf 0.22uf 0.47uf 0.22uf 0.47uf 0.22uf 0.47uf 330pf none 470pf 330pf none 470pf 330pf none 470pf 0.04ma .005ma 0.05ma 0.04ma .005ma 0.05ma 0.04ma .005ma 0.05ma specifications 10.5mh 4.2mh 1.6mh 2a 4a 6a 250 vac 40 c 45 c 66-xxx-020-0-12 66-xxx-020-0-04 66-xxx-020-0-14 66-xxx-020-0-06 66-xxx-020-1-12 66-xxx-020-1-04 66-xxx-020-1-14 66-xxx-020-1-06 66-xxx-020-4-12 66-xxx-020-4-04 66-xxx-020-4-14 66-xxx-020-4-06 66-xxx-040-0-12 66-xxx-040-0-04 66-xxx-040-0-14 66-xxx-040-0-06 66-xxx-040-1-12 66-xxx-040-1-04 66-xxx-040-1-14 66-xxx-040-1-06 66-xxx-040-4-12 66-xxx-040-4-04 66-xxx-040-4-14 66-xxx-040-4-06 66-xxx-060-0-12 66-xxx-060-0-04 66-xxx-060-0-14 66-xxx-060-0-06 66-xxx-060-1-12 66-xxx-060-1-04 66-xxx-060-1-14 66-xxx-060-1-06 66-xxx-060-4-12 66-xxx-060-4-04 66-xxx-060-4-14 66-xxx-060-4-06 none 0.22uf none 0.22uf none 0.22uf none 0.22uf none 0.22uf none 0.22uf none 0.22uf none 0.22uf none 0.22uf none 0.22uf none 0.22uf none 0.22uf none 0.22uf none 0.22uf none 0.22uf none 0.22uf none 0.22uf none 0.22uf rated rated leakage temp. model* voltage current current capacitance induct. rise 50/60hz (max.) c y c x1 c x2 (l 1 ) (max.) 0.22uf 0.47uf 0.22uf 0.47uf 0.22uf 0.47uf 0.22uf 0.47uf 0.22uf 0.47uf 0.22uf 0.47uf 0.22uf 0.47uf 0.22uf 0.47uf 0.22uf 0.47uf 330pf none 470pf 330pf none 470pf 330pf none 470pf .075ma .01ma 0.1ma .075ma .01ma .01ma .075ma .01ma 0.1ma tested and found to be iaw vde 0565 part 3 switched and fused filtered power entry modules 66-67-bsf/66-67-ssf series
50 ? level meter 50 ? 1 3 24 filter oscillator 50 ? 50 ? 50 ? level meter 50 ? 1 3 24 filter oscillator 50 ? 0.075 and 0.1 ma leakage current insertion loss (db) 80 frequency (mhz) 70 60 50 40 30 20 10 0 0.1 0.2 0.5 12 5 10 20 50 90 2 amp 6 amp 4 amp 0.075 and 0.1 ma leakage current insertion loss (db) 80 frequency (mhz) 70 60 50 40 30 20 10 0 0.1 0.2 0.5 12 5 10 20 50 90 2 amp 6 amp 4 amp switched and fused filtered power entry modules for medical or general purpose applications common mode normal mode 0.01 ma leakage current insertion loss (db) 80 frequency (mhz) 70 60 50 40 30 20 10 0 0.1 0.2 0.5 12 5 10 20 50 90 2 amp 6 amp 4 amp 0.01 ma leakage current insertion loss (db) 80 frequency (mhz) 70 60 50 40 30 20 10 0 0.1 0.2 0.5 12 5 10 20 50 90 2 amp 6 amp 4 amp dimensions .248 (6.3) 2.556 (65) 2.348 (59.7) 1.313 (33.4) 1.101 (28) fast-on tab #250 2.273 (57.8) 1.133 (28.8) 2.340 (59.5) panel cutout dimension mount from back side 1.514 (38.8) a r .079 (2.0) thickness of panel a .031 (0.8t) 2.430 (61.8 0.1) .039 (1.0t) 2.446 (62.2 0.1) .047 (1.2t) 2.462 (62.6 0.1) .059 (1.5t) 2.470 (62.8 0.1) .071 (1.8t) 2.473 (62.9 0.1) .079 (2.0t) 2.477 (63.0 0.1) * general tolerance .039 (1.0) * metal case 1.16 (29.5 ) +0.5 -0 +.02 -0 t= .031 (0.8) .248 (6.3) 2.556 (65) 2.348 (59.7) .142 (3.6) 1.947 (49.5) 1.573 (40 0.2) 1.101 (28) fast-on tab #250 2.273 (57.8) 1.133 (28.8) 2.340 (59.5) 1.573 (40. 0.2) 2.399 (61) panel cutout dimension mount from back side r .059 (1.5) 2 - .142 (3.6) hole 1.526 (38.8) 1.16 (29.5 ) +0.5 -0 +.02 -0 t= .031 (0.8) 66/67-bsf series 66/67-ssf series dimensions in inches (mm) 120 100 80 60 40 20 0 20 30 40 50 60 70 80 90 ambient temperature ( c) current (%) temperature characteristics 49 spectrum control inc. 8031 avonia rd. fairview, pa 16415 phone: 814-474-2207 fax: 814-474-2208 web site: www.spectrumcontrol.com spectrum control gmbh hansastrasse 6 91126 schwabach, germany phone: (49)-9122-795-0 fax: (49)-9122-795-58 switched and fused filtered power entry modules


▲Up To Search▲   

 
Price & Availability of 65-BSF-020-5-14

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X